Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator

After-sales Service: Free Spare Parts
Warranty: 1 Year
Cooling Method: Counter Flow
Ventilation Mode: Mechanical Ventilation
Material: PVC
Air Contact Form: Wet and Dry
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ordinary
Application Fields
Industrial
Condition
New
Color
Carbon Black
Thickness
0.3-0.5mm
Sheet Spacing
30mm
Usage
Cooling Tower
Transport Package
Wooden Crate
Specification
length random, width random, height 145mm
Trademark
Sinta
Origin
Hebei, China
HS Code
3926909090
Production Capacity
50000PCS/Month

Product Description

Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator

The Evaporative Condenser utilizes a NEW patented highly efficient PVC drift eliminator design. The drift eliminator removes entrained water droplets from the air stream to limit the drift rate to less than 0.001% of the recirculating water rate. With a low drift rate, the Evaporative Condenser saves valuable water and water treatment chemicals. The Evaporative Condenser can be located in areas where minimum water carryover is critical.
The drift eliminators are constructed of an inert polyvinyl chloride (PVC) plastic material which effectively eliminates corrosion of these vital components. They are assembled in sections to facilitate easy removal for inspection of the water distribution system. Eliminators incorporate UV inhibitors to resist cracking and degradation due to sunlight.
Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator
In all different types of cooling towers drift eliminators are used to reduce the loss of water and emissions. Above the water distribution and the cooling fills, a layer of drift eliminators is installed for this purpose. It catches the water drops which are carried away with the air flow and redirects them into the cooling water circuit. We are professional manufacturer of cooling tower parts, and we have different series of drift eliminators for your options. We can customize according to your request. Many contractors purchase from us with good feedback, we hope to assist you for next project! Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator


MAIN FEATURES of Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator:
Highly efficient drift removal drift loss
Self-extinguishing
Lightweight and easy to move
High mechanical strength
Resistant to chemical degradation and biological attack
Self-supporting structure
Interlocking panels designed to eliminate gaps between packs and avoid leaks

Item name
Efficient Water Cooling Tower PVC Drift Eliminators
Material
PVC,PP
Width
145mm
Length
1000mm,1200mm or as your request.
  Customization
Acceptable
      Sample
Available
Thickness
0.3-0.5mm
Applicable Temperature
 65°C~-35°C

 

 

Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator pictures:
Heavy Duty Construction Water Cooling Tower PVC Drift EliminatorHeavy Duty Construction Water Cooling Tower PVC Drift EliminatorHeavy Duty Construction Water Cooling Tower PVC Drift Eliminator
Heavy Duty Construction Water Cooling Tower PVC Drift EliminatorHeavy Duty Construction Water Cooling Tower PVC Drift Eliminator

Advantage for Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator:

1.Low Resistance and Low Cost
2.High Rigidity and Easy Assembly
3.High Efficiency
4.Long Life

This drift eliminator panel is made of solvent-bonded sheets of self-extinguishing, thermoformed PVC.
The drift eliminator's unique cellular design features overlapping PVC sheets. The result is a curved shape with three impact zones that capture the water droplets in the air stream, thereby reducing drift loss to less than 0.001% of circulating water flow. Furthermore, the properties of the material used, together with the drift eliminator's high mechanical strength, offer the highest level of protection against chemical degradation and weather exposure.

Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator

 

package:
Heavy Duty Construction Water Cooling Tower PVC Drift EliminatorHeavy Duty Construction Water Cooling Tower PVC Drift Eliminator

Other types cooling tower fill pictures:
Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator


cooling tower nozzle
Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator

drift eliminator
Heavy Duty Construction Water Cooling Tower PVC Drift Eliminator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now