Male & Female 3ft/4ft/5ft MX75 Cooling Tower Film Fill specification
product :cooling tower fill,pvc filler for cooling tower
1)Material: pvc, pp (100% new material or 80% new material )
2)Usage: cooling tower
3)Size: 915*1220mm,915*1854mm,915*any length,1220*1854mm,1220*any length,500*1000mm
4)Type: cooling tower part
Commodity | cooling tower fill |
width | 610mm.860mm,915mm, 1000mm, 1220mm, 1520mm |
Height | 1000mm, 1854mm, 2854mm |
Thickness | 0.27-0.6mm |
Male & Female 3ft/4ft/5ft MX75 Cooling Tower Film Fill features:
1. Improved water distribution
2. High thermal performance
3. Material meets Cooling Tower Institute
4.Mainly apply to Counterflow fill.
Male & Female 3ft/4ft/5ft MX75 Cooling Tower Film Fill Technical Data:
MX Fill is available in MX75 configuration and higher-performing MX625 configuration. MX is a hanging film type cooling tower fill which spreads the water into a thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow. This type of fill provides much more water surface exposure per cubic foot than splash type fill.
MX fill incorporates highly efficient cellular drift eliminators, integrally molded within the fill sheets. Compared with previous designs, these eliminators reduce drift emissions from the tower by a factor of ten or more! Less drift means tower owners save water bills and water treatment chemical expenses.
This fill virtually eliminates the nuisance caused by drift spotting on adjacent buildings and property. For additional savings, the drift eliminators discharge air directly toward the fan. Discharge air, traveling in the right direction when it leaves the eliminators, translates to lower fan horsepower.
Louvers are also integrally molded within the fill sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow. Unlike towers equipped with separate external louvers, this fill operates virtually ice-free even in extremely cold weather.
MX fill is thermoformed from PVC with a flame spread rating less than 25 per ASTM E-84 and is considered selfextinguishing. Therefore, the risk of fire damage is minimal.
We have many years for exported Cooling towers filling, we are professional for installation and production .
Male & Female 3ft/4ft/5ft MX75 Cooling Tower Film Fill Weight:
NOMINAL GAUGE |
DRY WEIGHT |
||
mils |
mm |
lbs/ft3 |
kg/m3 |
10 |
0.25 |
1.8 |
28.8 |
15 |
0.38 |
2.6 |
41.6 |
Above Data is for PVC material .