Customization: | Available |
---|---|
Type: | Perforator |
Certification: | CE, CCC, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specification | Rod Diameter (mm) | 4mm-18mm |
Rod Length (m) | 10m-500m (oem) | |
Frame Spec.(mm) | 1300x450x1330,1200x420x1220,980x350x1000, 680x240x700, etc |
|
Wheel Diameter(mm) | 300mm | |
Wall thickness of Metal Frame | 2.2mm | |
Color | blue, yellow, red, white etc | |
Material |
Rod Inner | Extruded by fiber glass and high strength resin at high temperature |
Rod Outer | High Density polyethylene coating | |
Iron Frame | Steel with high temperature sprayed plastic or Spray coating | |
Wheel | rubber | |
Brake | Yes | |
Drawing head | copper | |
Physical Characters | Density | 55g/m |
Working temperature | -40°C to +80°C | |
Breaking tension | 100kg | |
Bending Radius | 295mm | |
Technology | Pultrusion | |
Packaging | Inside | plastic woven strip wind around the frame |
Outside | carton |
Telecommunications: Pulling fiber optic cables through underground conduits.
Electrical Work: Installing wiring in commercial buildings or industrial plants.
HVAC Systems: Cleaning or inspecting air ducts.
Municipal Projects: Sewer line inspections and maintenance.
Preparation
Inspect the rodder for cracks or wear.
Attach connectors (e.g., hooks, eyes) to the leading end for cable linkage.
Deployment
Feed the rodder into the duct manually.
For long distances, join sections via threaded couplings.
Pulling Cables
Secure cables to the rodder's end using pull socks or swivels.
Apply steady tension; avoid jerking to prevent fiberglass splintering.
Retrieval
Withdraw the rodder slowly or detach modular segments.
Safety Tip: Wear gloves to protect against fiberglass splinters.