Fiberglass Duct Rodder in dispenser product overview
Introducing the New Slegers range of high quality, Cobra Snake Fibreglass Duct Rods.
Our rods are made from high quality fibreglass strands, coated with a tough yellow
Polypropylene (PP) to give a unique combination of strength and durability, of which
allows for greater wear resistance. The fibreglass core gives power & pushing stability
whereas the PP coating reduces friction to a minimum. As an added feature, all diameters
have a central copper trace wire, making it ideal for all locating type applications, and can
also be used as part of a CCTV pipe/conduit or cleaning system.
Fiberglass duct rod in dispenser technical specifications:
1.constructed of fiberglass reinforced in the center and consists of a rugged plastic layer that would ensure the lifetime of the flexible rod.
2.Excellent flexibility force.
3.Tensile strength about 500 Kgf.
4.designed for heavy duty applications ensuring greater rigidity and strength, while supporting additional forces without resentment to the multiple curvatures.
5.Wheel assembly for easy transportation.
6.Guide rollers and the right parts for rotary coupling.
7.Rolling bearing cage flotation (reel transport) for mobility should be light and easy to use in the field, including a parking brake for the flexible rod.
8. There is copper wire inside for tracing easily.
Fiberglass duct rodder in dispenser technical data
1.Glass reinforced composite core:
general properties
Property | value |
keinforcement | E-glass fiber |
glass content of inner part | 75-80% |
material of pulling rod | epoxy fiber glass(inner) high density polyethylene(outer) |
density | >1.9gr/cm3 |
diameter tolerance | +/-0.10mm |
work situation temperature | -40°C to +80°C |
Mechanical prperties
property | value |
minimum pullling strength | 4000 N+/-5% |
tensile modulus | >30000Mpa |
consistency of rod | 150gr/m +/-5% |
flexural modulus | >30000M pa |
elongation at break | 2.5-3% |
2. Polyethylene cover
Material:
Medium density polyethylene resin for the insulating and jacketing of telecommunications cables.
property | value |
tensile strength | >15N/mm2 |
environmental stress & crack resistance | >1000 hr. |
heat stability | OK. |
carbon black | OK. |
Fiberglass duct rodder in dispenser product pictures:
Marks: There is steel or copper trace wire inside for tracing easily.
Cable rodder accessories: