• Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media
  • Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media
  • Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media
  • Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media
  • Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media
  • Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

After-sales Service: Online Support
Warranty: 1 Year
Cooling Method: Cross Flow
Ventilation Mode: Natural Ventilation
Material: PVC or PP
Air Contact Form: Wet and Dry
Samples:
US$ 10/Square Meter 1 Square Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
CTF002
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
ISO
Condition
New
Width
760/915/1020/1220/1320/1520mm
Thickness
0.3-0.45mm
Weight
0.56kg
Colour
Black, Grey, etc
MOQ
50 Sheets
Usage
for Refrigerate
Absorption Rate
< 0.015%
Length
Customized
Sample
Provide
Transport Package
Pallet
Specification
760/915/1020/1220/1320/1520 x any length
Trademark
Longtime
Origin
China
Production Capacity
100000 Square Meters/Month

Product Description

Cross Flow Film Fill/EAC Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Cooling tower fill is a hanging film type cooling tower fill which incorporates highly efficient cellular drift eliminator and molded with the air inlet louver, spreads the water through the thin film, flowing over large vertical surfaces, promoting maximum exposure to air flow to get higher cooling efficiency. This type of fill provides much more water surface exposure per cubic foot than splash type fill.

Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill MediaCross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill MediaCross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Cross Flow Film Fill/EAC Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

FEATURES

-Applicable for cross flow type cooling towers
-Hanging or glue is available
-Incorporates highly efficient cellular drift eliminators, intergrally molded within the fill sheet
-Louvers are also integrally molded within the fill sheets preventing water from escaping and assuring precise air distribution throughout wide variations in airflow
-Thermoformed from PVC with a flame spread rating and considered self extinguishing

Cross Flow Film Fill/EAC Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Specification

With different request in cooling tower film fill, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. We could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
 
Module Length (Max)  mm 666
Module Width   mm 900/1000/1230
Module Depth   mm -
Flute Height  mm 19
Flute Corrugation Angle  degrees -
Surface Area  m2/m3 150
Sheet Thickness - Before Forming  mm 0.32
Sheet Thickness - After  Forming  mm 0.28
Max. application temp. (short time) - PVC  °C 60
Max.operating temp. (short time) - PP  °C 80
Customized size and thickness available for special request. Contact Newin for details!
 
 
Cross Flow Film Fill/EAC Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Detailed photos
Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill MediaCross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill MediaCross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Cross Flow Film Fill/EAC Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Application

Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill MediaCross Flow Film Fill/Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Our fatory
Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Cross Flow Film Fill/EAC Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media

Shipment

Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 100pcs

Cross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill MediaCross Flow Film Fill/Eac Cooling Tower Film Fills/PVC Cooling Tower Fill Packing/Cooling Tower Fill Media
FRQ

Q1. What's your Main Product ?
The company's main products are cooling tower and Cooling tower parts such as Film Fill, drift eliminator and spray system, FPR winding splash pipe, FRP profile parts,FRP gratings, etc

Q2:How to define the product price?
A: PVC cooling Tower  material is based on the thickness,vicat point, color, density,fire classification, packing and quantity.

Q3. Do you keep the stock of your products?
A: Yes, we maintain a certain amount of standard products inventory, in time to meet your needs.


Q4. Whether you have the ability to accept the product customization?
A: Products can be customized, we can make the new thermoforming or extruding mode based on your drawings and we can sign a confidentiality agreement about your patented product, pls contact us for any further information.

Q5: What's your delivery time ?
The delivery time normally will be 10 -30days , the specified delivery date will be according to customer request and order quantity .

Q6. How to reassure those who doubt the product quality and actual situations?
A professional system can ensure the whole latest development which will be monitored by you through the reports in the diffferent stages.

Q7.How about your after sale service?  

1. Warranty service
a).Warranty: 1 year.
b) .Warranty starting: acceptance date.  
2. Service commitment
Warranty period:
a). Our company will be responsible for the quality problems arising from the maintenance, replacement of parts and related materials.
b). Artificial damage will be repaired by our company, but the damaged devices shall be paid.
3. Expiration of the warranty period:
a). Our company provides lifelong maintenance, but the user is responsible for the cost of labor and material.
b). Our company also provides charging upgrades and improvements following to the customer's requirements.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now