• Different Types Industrial Cooling Tower PVC Drift Eliminator
  • Different Types Industrial Cooling Tower PVC Drift Eliminator
  • Different Types Industrial Cooling Tower PVC Drift Eliminator
  • Different Types Industrial Cooling Tower PVC Drift Eliminator
  • Different Types Industrial Cooling Tower PVC Drift Eliminator
  • Different Types Industrial Cooling Tower PVC Drift Eliminator

Different Types Industrial Cooling Tower PVC Drift Eliminator

After-sales Service: Yes
Warranty: 1 Year
Cooling Method: Counter Flow
Ventilation Mode: Natural Ventilation
Material: PP,PVC,FRP
Air Contact Form: Dry
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LT-C
Air Contact Way
Open
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Condition
New
Color
Carbon Black/Grey, etc
Shaping Mode
Plastic Extrusion Mould
Application
Crossflow, Counterflow ,Cooling Tower
Width
150mm, 300mm, 600mm/etc
Length
Any Length
Packing
Pallet
Name
Drift Eliminator /Vane Mist Eliminator
Usage
Cooling Tower
Hole Shape
Irregular
Shape
Customers′ Request
Technique
Punching
Filter Rating
99%
Thickness Range
0.8-1.0 mm
Materials
PVC
Transport Package
Wooden Pallet
Specification
customized
Trademark
LT
Origin
China
HS Code
3926909090
Production Capacity
100PCS/Week

Product Description

Cooling tower water drift eliminator

Product Description


Different Types Industrial Cooling Tower PVC Drift Eliminator

Drift Eliminators, made out of rigid PVC, are designed to remove entrained particles from air steam efficiently, with minimum pressure drop, thereby reducing the fan power requirement when the air passes through the Drift Eliminator. 
Water droplets are separated from the air drift at the three direction change points on the drift eliminator.
For Crossflow tower applications, the almost vertical water conduits provided by the SPC 100 drift eliminator remove the water droplets out of the drift eliminator area and return them back into the tower and does not allow any re-entry.
The special locking pin arrangement for SPC-100 facilitates quick and simple assembly at site


Different Types Industrial Cooling Tower PVC Drift Eliminator
 
TECHNICAL DATA
Characteristics SPC-100
Suggested Cooling Tower Application Crossflow
Type Of Structure P
Maximum Face Velocity (m/sec) 4.0
Module Length 600 - 3000 mm
Module Width 1200 mm or as required
Module Depth 100 mm
Distance Between Profiles 35
Directional changes for air flow 3
Maximum Continuous Temperature (°C) 60

Cooling tower drift eliminator are used to control water loss from a cooling tower by limiting the amount of circulating water droplets that are emitted with the exhaust air of the tower. Since drift droplets contain the same chemical and particulate matter of the circulating water from which they originate, they can cause numerous detrimental effects on surrounding equipment and the environment. The cooling tower industry uses drift rate to compare drift eliminator performance, a relationship that correlates droplet capture efficiency to the water circulation rate in a tower. drift eliminators are specifically designed to achieve maximum drift removal efficiency in both crossflow and counterflow tower applications with various product options available to minimize pressure drop, drift loss, cost, or a combination of all three
The panel size is customized according to clients' request.
The material could be PP or PVC material, welcome to contact us for more. We'll offer best price for you.


Cooling tower drift eliminator guarantee:

1. maximum operational safety;
2. legal compliance;
3. original therml performance of your cooling equipment;
4. easy cleaning;
5. dry surronding by minimum drift emission

Different Types Industrial Cooling Tower PVC Drift Eliminator

Feature of Water drift eliminator:

1). Its rate of drift is less than 0.001% of the circulating water flow rate, which is merely one fifth of the allowance value stipulated in GB7190.2-2008.The lower rate of drift helps to prolong the service life of fan due to decrease contact between the fan blade and the moist air, and helps to decrease the usage of chemical.

2). Lower rater of drift helps to reduce the impact to the boundary environment.

3). Its resistance is about 0.8mmH2O at 2.8m/s air velocity. Low resistance decreases the power consumption of fan, and reduces the cost.

4). Made of advanced PVC with additive to improve the performance of resistance ageing and anti-ultraviolet, its design life is 20 years.

5). Assembly with plug-in method increases rigidity and makes the assembly easier.



Why choose us              
 

1. Competitive price
With many years experience in this filed, we can give competitive price. As a manufacturer, we sale products directly there will not have any other cost.
2. Our quality guarantee
We make quality for each process before packing.Avoiding manufacturer defects
3. Fast delivery time 
Adopts advanced equipment and machines to production capacity for bulks,ensure the shipment soon,improve your efficiency.
4. FRP Conduit Snake Duct Rod Packing
Durable wooden pallet or carton, you can be sure the ordered items will reach your in perfect condition.

Different Types Industrial Cooling Tower PVC Drift Eliminator
Our service


 
  We offer professional products and fast delivery.
   We will help you solve problems when you use our products.
   Any question can turn to the technology department of our company.

 

  • Fast delivery  (Our factory has high production capacity and there is enough inventory to insure fast delivery for you)
  • 2. Competitive price (We are manuafacturer of our products, so we can provide you both high quality products and competitive price)
  • Quick response each inquiry within 24hours
  • Quanlity control strickly
  • Quick delivery imporve your effciency

Packaging & Shipping

Cooling tower drift eliminator

Delivery time:within 5-15days after deposit

Package:pallet,wooden box

Different Types Industrial Cooling Tower PVC Drift Eliminator
FAQ

1.Q: Are you Trading Company or Factory:

   A:.  We are Trading Company and also Factory

 2.Q: What's your production ability for one month?

     A:We can product Metric Tons per Month 200000 pcs  .

 3.Q:  What's your MOQ?

     A:50pcs

 4.Q:What's your shipping port?

    A:Tianjin,shanghai or any port as your reqirement 

 5.Q: What's your Payment Terms?

    A:L/C,T/T,Western Union  

Trial order is acceptable. Sample is available.

Welcome to inquire, we will feedback within  24 hours.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now