Warranty: 1years
Cooling Method: Counter Flow
Ventilation Mode: Natural Ventilation
Material: PVC/PP
Air Contact Form: Wet
Air Contact Way: Closed
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LTCF01
Tower Shape
Square
Noise Level
Low
Application Fields
Industrial
Certification
ISO, CE, CCC
Condition
New
Color
Carbon Black, etc
Thickness
0.25-0.4mm
Weight
600g/Square Meter
Shaping Mode
Plastic Extrusion Mould
Sheet Width
813,915,1220,1520mm
Sheet Spacing
19mm
Cooling Type
Cross Flow, Cross Flow/Counter Flow
Application
Cooling Tower
Sample
Free Sample of Cooling Tower Fill
Density
1.45g/cm3
Transport Package
in Bundle,Wooden Pallet/by Air,DHL,by Sea,by Train
Specification
620mm*1080mm / ECT
Trademark
LT
Origin
Hebei
HS Code
3926909090
Production Capacity
100000 PCS/Month

Product Description

PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill

The ML cooling tower fill is one of famous and popular PVC cross flow fill in all of the brands cooling tower fill. It is good sales in the worldwide and have a good lifetime in
use.
PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill


WORKING PRINCIPLE

ML cooling tower include drift eliminator two sides itself and have certain 5 degree inclination which is requested in the hanging. Why it need some angles inclination?
The reason is two side honeycomb and drift eliminator after connecting one by one, that will decrease the splash of water droplets in the water flow falling. That will reduce the water loss and wastage. If the wastage is less 0.001%, it is meet the standard. But if it is more than 0.001%, please check the ML cooling tower fill installation and make sure the right PVC fill size and quantity of the loose sheets. Only after making sure the cool air meet hot water enough, the temperature reduction is more effective.
PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill
PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill
We, LongTime company supply different sizes for ML cooling tower fill for customers. The thickness is from 0.3mm to 0.45mm and the raw material PVC sheets are requested in good quality and strong enough for the ML fill. The width are 610mm, 750mm,813mm,915mm,1000mm,1220mm,1520mm, the new mould and machine for 1900mm width ML fill is in development.We believe it will be successful in the near future, that will bring much convenient for customer in the installation and application.

The length of ML cooling tower fill can be customized. The normal length are 1854mm,2060mm,2450mm,2678mm,2980mm,3090mm. The pitch is 19-20mm, that means the distance between two loose fill sheets is 19-20mm.It is hanging on the fiberglass tubes in the cooling tower 2 sides. And it has A type and B type which make two loose sheets joint points match very well.
PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill
PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill

PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill

Name: cross flow cooling tower fill
Type: Cooling Tower Parts
Unit: PC
Material: PVC
Dimension Width usually be 1220,1500,915,813,length can be meet your demands
Thickness usually be 0.25mm,0.38mm,also can be customized
Usage: For cooling tower
color clear black green blue
Shaping mode Plastic extrusion mould
Brand Name: Longtime
Place of origin: Hebei,China
Minimum Order: 1000 PCS
Packaging Details: In bundle,wooden pallet or as your request
Terms of payment: T/T
Sample delivery time: 5-10 days
Supply Ability: 200000 sets/month
Production date: Within  20days after deposit

PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill
PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill


 cooling tower fill fetures:
1. Improved water distribution
2. High thermal performance
3. Material meets Cooling Tower Institute
4.Mainly apply to Counterflow fill
Usage of  cooling tower fill

 

PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill
 

 Packaging & Shipping
Cooling tower material

Delivery time:within 5-15days after deposit

Package:pallet,wooden box

PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill

We Langtime supply ever types of EAC cooling tower fill as the following photo shows:

PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill

Cooling tower fill Factory production pictures

PVC Filler/ Width 1220mm/1520mm /915mm/813mm Cooling Tower Fill

 

FAQ

1.Q: Are you Trading Company or Factory:

   A:.  We are Trading Company and also Factory

 2.Q: What's your production ability for one month?

     A:We can product Metric Tons per Month 200000 pcs  .

 3.Q:  What's your MOQ?

     A:500pcs

 4.Q:What's your shipping port?

    A:Tianjin,shanghai or any port as your reqirement 

 5.Q: What's your Payment Terms?

    A:L/C,T/T,Western Union  

Try order is acceptable. Sample is available.

Welcome to inquire, we will feedback within  24 hours.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now