Marley Cooling Tower Cellular PVC Drift Eliminator Manufacturer

Warranty: 1 Year
Cooling Method: Counter Flow
Ventilation Mode: Natural Ventilation
Material: PVC
Air Contact Form: Wet
Air Contact Way: Closed
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LTDE01
Tower Shape
Round/Square
Noise Level
Low
Application Fields
Industrial
Condition
New
Color
Carbon Black, etc
Thickness
0.25-0.4mm
Flute Height
39mm
Dimension
Width 145mm, Length Random
Weight
600g/Square Meter
Shaping Mode
Plastic Extrusion Mould
Application
Cooling Tower
Cooling Type
Cross Flow, Cross Flow/Counter Flow
Sample
Available
Factory
Hengshui, China
Transport Package
in Bundle,Wooden Pallet/by Air,DHL,by Sea,by Train
Specification
145mm
Trademark
LT
Origin
Hebei
HS Code
3926909090
Production Capacity
100000 PCS/Month

Product Description

Low Drift Rate & Low Pressure Drop Marley cooling tower drift eliminator is developed when eliminator designs were primarily ineffective blade type configurations. The XCEL generation of eliminators is patented later. No other eliminator could come close to
XCEL eliminator's low drift rate and low pressure drop. Now, virtually every eliminator is a nesting cellular PVC type design.

XCELplus is a more advanced design that meets or exceeds today's demanding specifications for drift emissions without sacrificing fan horsepower. Drift rates are currently half that of the original XCEL design with equivalent pressure drop.

The eliminator discharge angle is important enough to warrant two separate eliminator designs-one for crossflow and one for counterflow towers. Tests show the air direction leaving the eliminator is extremely important-imperfect designs create additional work for the fan. This means either increased fan horsepower-or reduced cooling tower performance. The crossflow version features drainage slots within the eliminator pack to ensure trapped drift is returned to the wet side of the cooling tower.

 

Low drift rate is the primary goal of eliminator design. XCELplus boasts typical drift rates of .001% of the total GPM. Lower drift rates are available depending upon tower configuration. Considering low drift rates and low pressure drop, XCELplus is one of
the most effective cooling tower drift eliminator available in the market place today.

/ Suggested Specification /

Drift eliminators shall be of cellular type, Marley XCELplus or approved equal. The eliminators shall be thermoformed from 17 mil (.017″) PVC (polyvinyl chloride) material into a configuration providing at least three changes of air direction and solvent welded into multiple sheet packs. Flame spread rating of the material must not exceed 25 per ASTM E-84. Eliminators used in crossflow towers must provide a discharge angle (as defined by the angle of the last section of the eliminator itself) of at least 42° from the horizontal when installed. 

 

The mass drift quantity, determined by the CTI Drift Test Code ATC-140 shall not exceed _______% of the total GPM and shall be guaranteed for all operating conditions.
The eliminator packs shall be able to span 66″ unsupported for counterflow configurations and 72″ for crossflow, with minimal deflection at design conditions. Eliminators shall be FM approved. 
Eliminator packs shall measure up to 24″ wide, 5.75″ in depth and up to 12′-0″ long.

Marley Cooling Tower Drift Eliminator pictures:

Marley Cooling Tower Cellular PVC Drift Eliminator Manufacturer

Marley Cooling Tower Cellular PVC Drift Eliminator Manufacturer
Marley Cooling Tower Cellular PVC Drift Eliminator Manufacturer
 

 

Marley drift eliminator package:

Marley Cooling Tower Cellular PVC Drift Eliminator Manufacturer
 

Cooling tower drift eliminator application:

 Marley Cooling Tower Cellular PVC Drift Eliminator Manufacturer

 

Other cooling tower drift eliminator pictures:

 Marley Cooling Tower Cellular PVC Drift Eliminator Manufacturer

Cooling tower drift eliminator also can be made as your requests.

FAQ

1.Q: Are you Trading Company or Factory:

   A:.  We are Trading Company and also Factory

 2.Q: What's your production ability for one month?

     A:We can product Metric Tons per Month 200000 pcs  .

 3.Q:  What's your MOQ?

     A:500pcs

 4.Q:What's your shipping port?

    A:Tianjin,shanghai or any port as your reqirement 

 5.Q: What's your Payment Terms?

    A:L/C,T/T,Western Union  

Try order is acceptable. Sample is available.

Welcome to inquire, we will feedback within  24 hours.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now